Safety sleeve SMH application
The Schuck safety sleeve was specially developed to be able to work safely at higher operating pressures of up to 4 bar. The sizes are matched to the 4 bar bladder setting device from Hütz and Baumgarten. The increased safety is made possible by a special sealing system, which has to be activated by a 2 component resin during construction site assembly and ensures that the sealing rings are pressed securely.
- PN 16 to PN 100
- DN 80 to DN 200
- temperature range from -10°C to +50°C
- processing pressure up to 4.0 bar
- operating medium gas (fluid group 1)
- for pressure up to 1 bar see “SMU”